{"id":18665,"date":"2020-07-29T15:17:06","date_gmt":"2020-07-29T15:17:06","guid":{"rendered":"https:\/\/abbigliamentocertificato.com\/abbigliamento_di_protezione_arco_elettrico\/"},"modified":"2023-11-10T18:56:03","modified_gmt":"2023-11-10T16:56:03","slug":"clothing_for_protection_against_electric_arc","status":"publish","type":"page","link":"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/","title":{"rendered":"EN 61482 \u2013 Clothing for protection against Electric Arc"},"content":{"rendered":"<h1 style=\"text-align: center;\">IEC 61482<br \/><span style=\"font-size: 0.8em;\">\u00a0<strong>Protective Clothing for Electric Arc Protection<\/strong><\/span><\/h1>\r\n<p><span style=\"font-weight: 400;\">Standards IEC 61482-1-1:2019 and IEC 61482-1-2:2019 specify the requirements and test methods that protective clothing and materials related to heat and flame-resistant clothing for workers exposed to electric arcs must adhere to.<br \/>The garments undergo specific tests to <strong>determine<\/strong>:<\/span><\/p>\r\n<ul>\r\n<li>The <strong>ATPV<\/strong> (Arc Thermal Performance Value) and <strong>EBT<\/strong> (energy break-open threshold) value;<\/li>\r\n<li>The arc flash protection <strong>class.<\/strong><\/li>\r\n<\/ul>\r\n<h2>What&#8217;s Electric Arc?<\/h2>\r\n<div class=\"wp-block-image\">\r\n<figure class=\"alignright size-large is-resized\"><img decoding=\"async\" class=\"alignnone wp-image-3935\" src=\"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/arco-elettrico-def.jpg\" alt=\"Abbigliamentoantinfortunistico di protezione dall'Arco Elettrico\" width=\"415\" \/><\/figure>\r\n<\/div>\r\n<p><b>An electric arc is a continuous, high-voltage electric discharge<\/b><span style=\"font-weight: 400;\"> that occurs <\/span><b>accidentally<\/b><span style=\"font-weight: 400;\"> and <\/span><b>unexpectedly<\/b><span style=\"font-weight: 400;\"> between two conductors. This electrical discharge is accompanied by a <\/span><b>strong glow, intense heat<\/b><span style=\"font-weight: 400;\">, and often a wave of high pressure, noise, and toxic fumes.<\/span><br \/>An electric arc can occur <span style=\"font-weight: 400;\">due to<\/span>:<\/p>\r\n<ul>\r\n<li><strong><span style=\"font-weight: 400;\">System<\/span>overvoltages;<\/strong><\/li>\r\n<li><strong>Melting<\/strong> overloaded conductors;<\/li>\r\n<li><span style=\"font-weight: 400;\">The <\/span><b>presence of moisture or conductive dust <\/b><span style=\"font-weight: 400;\">that interferes with the surface insulation of an insulator.<\/span><\/li>\r\n<\/ul>\r\n<p>The temperatures resulting from the electric arc<strong> can exceed 10,000\u00b0C<\/strong> <span style=\"font-weight: 400;\">and can lead to <\/span> <strong>fires with explosions<\/strong>, <strong>metal vaporization<\/strong>, intense<strong> emission of ultraviolet rays<\/strong> <span style=\"font-weight: 400;\">the formation of <\/span><strong>toxic gases<\/strong> and <span style=\"font-weight: 400;\">excessive <\/span><strong>noise<\/strong>.<\/p>\r\n<p><span style=\"font-weight: 400;\">These factors can cause varying degrees of harm to the operator depending on their <strong>health and the duration<\/strong> and manner of <strong>exposure<\/strong> to the electric arc. This harm can include:<\/span><\/p>\r\n<ul>\r\n<li><strong>Increased pressure;<\/strong><\/li>\r\n<li><strong>Toxic influences<\/strong> <span style=\"font-weight: 400;\">due to the<\/span> <strong>melting of the casings;<\/strong><\/li>\r\n<li><strong>Cardiac arrest;<\/strong><\/li>\r\n<li><strong>Second or third-degree burns<\/strong>, which are the most common injuries<\/li>\r\n<li><strong>Fractures or damage to internal organs;<\/strong><\/li>\r\n<li><strong>Involuntary muscle contraction<\/strong>, which can result in sudden and dangerous movements, falls, and other accidents.<\/li>\r\n<\/ul>\r\n<p><span style=\"font-weight: 400;\">The occurrence of an electric arc poses a severe, <\/span>, <strong style=\"font-size: 16px;\">potentially lethal risk.<\/strong><\/p>\r\n<h3>Scope<\/h3>\r\n<p><span style=\"font-weight: 400;\">The energy generated by an electric arc can ignite standard protective clothing.<\/span> <span style=\"font-weight: 400;\">Therefore, workers exposed to this risk must be adequately protected.\u00a0 <\/span><\/p>\r\n<p><span style=\"font-weight: 400;\">These garments are primarily used by personnel who work with <strong>electrical cabinets<\/strong> or <strong>panels, electricians<\/strong> who frequently handle conductive <strong>materials or electrical systems<\/strong>, and other workers at risk in <strong>chemical plants and refineries.<\/strong><\/span><\/p>\r\n<div class=\"wp-block-image\">\r\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" class=\"alignnone wp-image-3932\" src=\"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/Test-arco-elttrico-def-piccola.jpg\" alt=\"\" width=\"651\" height=\"234\" \/><\/figure>\r\n<\/div>\r\n<h3>General requirements<\/h3>\r\n<p><strong><span style=\"font-weight: 400;\">Protective workwear designed to ensure safety in environments with a potential electric arc presence must comply with the test methods outlined in the <\/span>IEC EN 61482-1-1:2019<\/strong> standard.<\/p>\r\n<ul>\r\n<li>The <strong>ATPV<\/strong> value (Arc Thermal Performance Value) <b>signifies the maximum thermal energy a fabric can withstand before the worker suffers second-degree burns<\/b>;<\/li>\r\n<li>The <strong>EBT (energy limit of breakage)<\/strong> <span style=\"font-weight: 400;\">value indicates the maximum exposure to energy that a garment can endure without breaking.<\/span><\/li>\r\n<\/ul>\r\n<p><span style=\"font-weight: 400;\">The arc resistance of a fabric is, therefore, determined by its ATPV or EBT.<\/span><\/p>\r\n<p><strong>The IEC EN 61482-1-2:2019<\/strong> standard, <strong>the test is carried to the closed arc<\/strong>: <span style=\"font-weight: 400;\">an electric arc is recreated in a highly confined environment using special electrodes, with the fabric exposed.<\/span><br \/>This test classifies the fabrics into <strong>two classifications:<\/strong><\/p>\r\n<ul>\r\n<li><strong>Class 1<\/strong>, <span style=\"font-weight: 400;\">where <\/span>the fabric must remain intact at <strong>4 KA short circuit condition for a time of 0.5 seconds<\/strong>, protecting the operator from second-degree burns;<\/li>\r\n<li><strong>Class 2<\/strong>,<span style=\"font-weight: 400;\">\u00a0where<\/span> the fabric must remain intact at <strong>7 KA short circuit conditions for a time of 0.5 seconds,<\/strong> protecting the operator from second-degree burns.<\/li>\r\n<\/ul>\r\n<p><span style=\"font-weight: 400;\">The arc resistance of a garment corresponds to the fabric class it is made of.<\/span><\/p>\r\n<h2>More on the IEC 61482 standard<\/h2>\r\n<h4>THE STOLL CURVE<\/h4>\r\n<p>The Stoll Curve is a <strong>mathematical model<\/strong> that allows us to quantify <strong>the response of human skin and tissues to heat energy sources. <\/strong><\/p>\r\n<p><span style=\"font-weight: 400;\">When tissues transition from <strong>36\u00b0C<\/strong> (body temperature) to <strong>45\u00b0C, burns<\/strong> begin to occur. Beyond 50\u00b0C, skin damage occurs <strong>100 times faster than at 45\u00b0C<\/strong>, while at <strong>72\u00b0C<\/strong>, the skin undergoes <strong>instant and complete destruction.<\/strong><\/span><\/p>\r\n<div class=\"wp-block-image\">\r\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" class=\"wp-image-3945\" src=\"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/ustioni-EN.png\" alt=\"\" \/><\/figure>\r\n<\/div>\r\n<p><span style=\"font-weight: 400;\">As a result of these studies,<strong> special calorimetric sensors<\/strong> have been developed to <strong>replicate the skin&#8217;s reaction to exposure to flames.<\/strong> These sensors, when placed on fabrics or mannequins and subjected to the closed arc test, predict the onset of second or third-degree burns.<\/span><\/p>\r\n\r\n<h3 class=\"has-text-align-center wp-block-heading\">Discover the <span style=\"font-weight: 400;\">\u00a0<strong>features <\/strong><\/span>of the other safety clothing<\/h3>\r\n\r\n\r\n\r\n<div class=\"wp-block-buttons aligncenter is-layout-flex wp-block-buttons-is-layout-flex\">\r\n\r\n\r\n<div class=\"wp-block-button is-style-outline is-style-outline--1 is-layout-flex wp-block-buttons-is-layout-flex\"><a class=\"wp-block-button__link has-text-color has-background\" style=\"background-color: #c6c6c6; color: #445766;\" href=\"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/\"><strong>ELECTRIC ARC<\/strong><\/a><\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-button is-style-outline--2\"><a class=\"wp-block-button__link has-background\" style=\"background-color: #445766;\" href=\"https:\/\/abbigliamentocertificato.com\/en\/abbigliamento_esd\/\"><strong>ESD<\/strong><\/a><\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-button is-style-outline--3\"><a class=\"wp-block-button__link has-background\" style=\"background-color: #445766;\" href=\"https:\/\/abbigliamentocertificato.com\/en\/abbigliamento_antistatico\/\"><strong>ANTI-STATIC<\/strong><\/a><\/div>\r\n<\/div>\r\n\r\n\r\n\r\n<p style=\"text-align: center;\">Visit our website and explore all the <a href=\"https:\/\/abbigliamentocertificato.com\/en\/category\/en-61482-electric-arc-protection\/\">Arc Protection Garments<\/a><\/p>\r\n\r\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>IEC 61482\u00a0Protective Clothing for Electric Arc Protection Standards IEC 61482-1-1:2019 and IEC 61482-1-2:2019 specify the requirements and test methods that protective clothing and materials related to heat and flame-resistant clothing for workers exposed to electric arcs must adhere to.The garments undergo specific tests to determine: The ATPV (Arc Thermal Performance Value) and EBT (energy break-open [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":19454,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-18665","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Electric Arc Protective Clothing | All about IEC 61482<\/title>\n<meta name=\"description\" content=\"If the workers of your company are exposed to electric arcs, read more about the standard on protective clothing online, on AbbigliamentoCertificato.com\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Electric Arc Protective Clothing | All about IEC 61482\" \/>\n<meta property=\"og:description\" content=\"If the workers of your company are exposed to electric arcs, read more about the standard on protective clothing online, on AbbigliamentoCertificato.com\" \/>\n<meta property=\"og:url\" content=\"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/\" \/>\n<meta property=\"og:site_name\" content=\"abbigliamentocertificato.com\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-10T16:56:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/Arcoelettrico-5.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"3200\" \/>\n\t<meta property=\"og:image:height\" content=\"900\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/\",\"url\":\"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/\",\"name\":\"Electric Arc Protective Clothing | All about IEC 61482\",\"isPartOf\":{\"@id\":\"https:\/\/abbigliamentocertificato.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/Arcoelettrico-5.jpg\",\"datePublished\":\"2020-07-29T15:17:06+00:00\",\"dateModified\":\"2023-11-10T16:56:03+00:00\",\"description\":\"If the workers of your company are exposed to electric arcs, read more about the standard on protective clothing online, on AbbigliamentoCertificato.com\",\"breadcrumb\":{\"@id\":\"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/#primaryimage\",\"url\":\"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/Arcoelettrico-5.jpg\",\"contentUrl\":\"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/Arcoelettrico-5.jpg\",\"width\":3200,\"height\":900,\"caption\":\"Arcoelettrico\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/abbigliamentocertificato.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"EN 61482 \u2013 Clothing for protection against Electric Arc\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/abbigliamentocertificato.com\/en\/#website\",\"url\":\"https:\/\/abbigliamentocertificato.com\/en\/\",\"name\":\"abbigliamentocertificato.com\",\"description\":\"Under Construction\",\"publisher\":{\"@id\":\"https:\/\/abbigliamentocertificato.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/abbigliamentocertificato.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/abbigliamentocertificato.com\/en\/#organization\",\"name\":\"abbigliamentocertificato.com\",\"url\":\"https:\/\/abbigliamentocertificato.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/abbigliamentocertificato.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/LogoAbbigliamentoCertificato-2-e1648482177982.png\",\"contentUrl\":\"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/LogoAbbigliamentoCertificato-2-e1648482177982.png\",\"width\":1000,\"height\":308,\"caption\":\"abbigliamentocertificato.com\"},\"image\":{\"@id\":\"https:\/\/abbigliamentocertificato.com\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Electric Arc Protective Clothing | All about IEC 61482","description":"If the workers of your company are exposed to electric arcs, read more about the standard on protective clothing online, on AbbigliamentoCertificato.com","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/","og_locale":"en_US","og_type":"article","og_title":"Electric Arc Protective Clothing | All about IEC 61482","og_description":"If the workers of your company are exposed to electric arcs, read more about the standard on protective clothing online, on AbbigliamentoCertificato.com","og_url":"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/","og_site_name":"abbigliamentocertificato.com","article_modified_time":"2023-11-10T16:56:03+00:00","og_image":[{"width":3200,"height":900,"url":"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/Arcoelettrico-5.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/","url":"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/","name":"Electric Arc Protective Clothing | All about IEC 61482","isPartOf":{"@id":"https:\/\/abbigliamentocertificato.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/#primaryimage"},"image":{"@id":"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/#primaryimage"},"thumbnailUrl":"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/Arcoelettrico-5.jpg","datePublished":"2020-07-29T15:17:06+00:00","dateModified":"2023-11-10T16:56:03+00:00","description":"If the workers of your company are exposed to electric arcs, read more about the standard on protective clothing online, on AbbigliamentoCertificato.com","breadcrumb":{"@id":"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/#primaryimage","url":"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/Arcoelettrico-5.jpg","contentUrl":"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/Arcoelettrico-5.jpg","width":3200,"height":900,"caption":"Arcoelettrico"},{"@type":"BreadcrumbList","@id":"https:\/\/abbigliamentocertificato.com\/en\/clothing_for_protection_against_electric_arc\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/abbigliamentocertificato.com\/en\/"},{"@type":"ListItem","position":2,"name":"EN 61482 \u2013 Clothing for protection against Electric Arc"}]},{"@type":"WebSite","@id":"https:\/\/abbigliamentocertificato.com\/en\/#website","url":"https:\/\/abbigliamentocertificato.com\/en\/","name":"abbigliamentocertificato.com","description":"Under Construction","publisher":{"@id":"https:\/\/abbigliamentocertificato.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/abbigliamentocertificato.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/abbigliamentocertificato.com\/en\/#organization","name":"abbigliamentocertificato.com","url":"https:\/\/abbigliamentocertificato.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/abbigliamentocertificato.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/LogoAbbigliamentoCertificato-2-e1648482177982.png","contentUrl":"https:\/\/abbigliamentocertificato.com\/wp-content\/uploads\/LogoAbbigliamentoCertificato-2-e1648482177982.png","width":1000,"height":308,"caption":"abbigliamentocertificato.com"},"image":{"@id":"https:\/\/abbigliamentocertificato.com\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/abbigliamentocertificato.com\/en\/wp-json\/wp\/v2\/pages\/18665","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/abbigliamentocertificato.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/abbigliamentocertificato.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/abbigliamentocertificato.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/abbigliamentocertificato.com\/en\/wp-json\/wp\/v2\/comments?post=18665"}],"version-history":[{"count":0,"href":"https:\/\/abbigliamentocertificato.com\/en\/wp-json\/wp\/v2\/pages\/18665\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/abbigliamentocertificato.com\/en\/wp-json\/wp\/v2\/media\/19454"}],"wp:attachment":[{"href":"https:\/\/abbigliamentocertificato.com\/en\/wp-json\/wp\/v2\/media?parent=18665"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}